LOT Quantum Design vibrating sample magnetometer lot- quantum design
Vibrating Sample Magnetometer Lot Quantum Design, supplied by LOT Quantum Design, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/vibrating sample magnetometer lot- quantum design/product/LOT Quantum Design
Average 90 stars, based on 1 article reviews
vibrating sample magnetometer lot- quantum design - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
LOT Quantum Design vibrating sample magnetometer
Vibrating Sample Magnetometer, supplied by LOT Quantum Design, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/vibrating sample magnetometer/product/LOT Quantum Design
Average 90 stars, based on 1 article reviews
vibrating sample magnetometer - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
LOT Quantum Design vibrating-sample magnetometer vsm versalab-qd
Vibrating Sample Magnetometer Vsm Versalab Qd, supplied by LOT Quantum Design, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/vibrating-sample magnetometer vsm versalab-qd/product/LOT Quantum Design
Average 90 stars, based on 1 article reviews
vibrating-sample magnetometer vsm versalab-qd - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
LOT Quantum Design microsense vibrating sample magnetometer (vsm)
(a,b) Schematic representation of the electric contacts and the homemade cell setup for in situ liquid-gated <t>VSM</t> measurements, where WE and CE represent the working electrode and counter electrode, respectively. (c) Scheme showing the oxygen ion migration phenomenon on the microdisks viewed from the lateral side under application of negative voltage to the sample.
Microsense Vibrating Sample Magnetometer (Vsm), supplied by LOT Quantum Design, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microsense vibrating sample magnetometer (vsm)/product/LOT Quantum Design
Average 90 stars, based on 1 article reviews
microsense vibrating sample magnetometer (vsm) - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
LOT Quantum Design vibrating sample magnetometer option of a qd ppms 14
(a,b) Schematic representation of the electric contacts and the homemade cell setup for in situ liquid-gated <t>VSM</t> measurements, where WE and CE represent the working electrode and counter electrode, respectively. (c) Scheme showing the oxygen ion migration phenomenon on the microdisks viewed from the lateral side under application of negative voltage to the sample.
Vibrating Sample Magnetometer Option Of A Qd Ppms 14, supplied by LOT Quantum Design, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/vibrating sample magnetometer option of a qd ppms 14/product/LOT Quantum Design
Average 90 stars, based on 1 article reviews
vibrating sample magnetometer option of a qd ppms 14 - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
LOT Quantum Design superconductive quantum interference device–vibrating sample magnetometer
(a,b) Schematic representation of the electric contacts and the homemade cell setup for in situ liquid-gated <t>VSM</t> measurements, where WE and CE represent the working electrode and counter electrode, respectively. (c) Scheme showing the oxygen ion migration phenomenon on the microdisks viewed from the lateral side under application of negative voltage to the sample.
Superconductive Quantum Interference Device–Vibrating Sample Magnetometer, supplied by LOT Quantum Design, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/superconductive quantum interference device–vibrating sample magnetometer/product/LOT Quantum Design
Average 90 stars, based on 1 article reviews
superconductive quantum interference device–vibrating sample magnetometer - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
LOT Quantum Design vibrating sample magnetometer vsm
(a,b) Schematic representation of the electric contacts and the homemade cell setup for in situ liquid-gated <t>VSM</t> measurements, where WE and CE represent the working electrode and counter electrode, respectively. (c) Scheme showing the oxygen ion migration phenomenon on the microdisks viewed from the lateral side under application of negative voltage to the sample.
Vibrating Sample Magnetometer Vsm, supplied by LOT Quantum Design, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/vibrating sample magnetometer vsm/product/LOT Quantum Design
Average 90 stars, based on 1 article reviews
vibrating sample magnetometer vsm - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
LOT Quantum Design microsense lot-quantumdesign vibrating sample magnetometer
Schematic of the cell built for applying an electric field in situ while measuring the magnetic properties in a Vibrating Sample <t>Magnetometer.</t> The electrochemical cell contained the CFO sample as the working electrode and a Pt wire counter electrode. The working electrode contact was made to the Pt underneath the CFO sample. The electrolyte was propylene carbonate with a small amount of dissolved NaOH. The whole cell was attached to a VSM holder and vibrated vertically between the magnetic field coils. The inset shows the layers of the sample from a side view with the Pt counter electrode.
Microsense Lot Quantumdesign Vibrating Sample Magnetometer, supplied by LOT Quantum Design, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microsense lot-quantumdesign vibrating sample magnetometer/product/LOT Quantum Design
Average 90 stars, based on 1 article reviews
microsense lot-quantumdesign vibrating sample magnetometer - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
LOT Quantum Design vibrating sample magnetometer ez9 microsense
Schematic of the cell built for applying an electric field in situ while measuring the magnetic properties in a Vibrating Sample <t>Magnetometer.</t> The electrochemical cell contained the CFO sample as the working electrode and a Pt wire counter electrode. The working electrode contact was made to the Pt underneath the CFO sample. The electrolyte was propylene carbonate with a small amount of dissolved NaOH. The whole cell was attached to a VSM holder and vibrated vertically between the magnetic field coils. The inset shows the layers of the sample from a side view with the Pt counter electrode.
Vibrating Sample Magnetometer Ez9 Microsense, supplied by LOT Quantum Design, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/vibrating sample magnetometer ez9 microsense/product/LOT Quantum Design
Average 90 stars, based on 1 article reviews
vibrating sample magnetometer ez9 microsense - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
LOT Quantum Design vibrating sample magnetometer squid-vsm magnetometer
Schematic of the cell built for applying an electric field in situ while measuring the magnetic properties in a Vibrating Sample <t>Magnetometer.</t> The electrochemical cell contained the CFO sample as the working electrode and a Pt wire counter electrode. The working electrode contact was made to the Pt underneath the CFO sample. The electrolyte was propylene carbonate with a small amount of dissolved NaOH. The whole cell was attached to a VSM holder and vibrated vertically between the magnetic field coils. The inset shows the layers of the sample from a side view with the Pt counter electrode.
Vibrating Sample Magnetometer Squid Vsm Magnetometer, supplied by LOT Quantum Design, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/vibrating sample magnetometer squid-vsm magnetometer/product/LOT Quantum Design
Average 90 stars, based on 1 article reviews
vibrating sample magnetometer squid-vsm magnetometer - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
LOT Quantum Design vibrating sample magnetometry ade magnetometer with 3t electromagnet
Schematic of the cell built for applying an electric field in situ while measuring the magnetic properties in a Vibrating Sample <t>Magnetometer.</t> The electrochemical cell contained the CFO sample as the working electrode and a Pt wire counter electrode. The working electrode contact was made to the Pt underneath the CFO sample. The electrolyte was propylene carbonate with a small amount of dissolved NaOH. The whole cell was attached to a VSM holder and vibrated vertically between the magnetic field coils. The inset shows the layers of the sample from a side view with the Pt counter electrode.
Vibrating Sample Magnetometry Ade Magnetometer With 3t Electromagnet, supplied by LOT Quantum Design, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/vibrating sample magnetometry ade magnetometer with 3t electromagnet/product/LOT Quantum Design
Average 90 stars, based on 1 article reviews
vibrating sample magnetometry ade magnetometer with 3t electromagnet - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

Image Search Results


(a,b) Schematic representation of the electric contacts and the homemade cell setup for in situ liquid-gated VSM measurements, where WE and CE represent the working electrode and counter electrode, respectively. (c) Scheme showing the oxygen ion migration phenomenon on the microdisks viewed from the lateral side under application of negative voltage to the sample.

Journal: ACS Applied Materials & Interfaces

Article Title: Composition-Dependent Voltage-Driven OFF-ON Switching of Ferromagnetism in Co–Ni Oxide Microdisks

doi: 10.1021/acsami.4c15739

Figure Lengend Snippet: (a,b) Schematic representation of the electric contacts and the homemade cell setup for in situ liquid-gated VSM measurements, where WE and CE represent the working electrode and counter electrode, respectively. (c) Scheme showing the oxygen ion migration phenomenon on the microdisks viewed from the lateral side under application of negative voltage to the sample.

Article Snippet: A LOT-QuantumDesign MicroSense Vibrating Sample Magnetometer (VSM) was used to characterize the magnetic properties of the samples after annealing.

Techniques: In Situ, Migration

(a) VSM characterization of the Ni 25 Co 75 oxide microdisks, demonstrating the comparison between the hysteresis loops in the as-annealed OFF (black), treated ON (red) and recovered re-OFF (blue) states. (b,c) Dependence of M on actuation time, during the respective negative and positive voltage steps. (d-f) display the same OFF-ON-OFF information for the Ni 50 Co 50 oxide microdisks.

Journal: ACS Applied Materials & Interfaces

Article Title: Composition-Dependent Voltage-Driven OFF-ON Switching of Ferromagnetism in Co–Ni Oxide Microdisks

doi: 10.1021/acsami.4c15739

Figure Lengend Snippet: (a) VSM characterization of the Ni 25 Co 75 oxide microdisks, demonstrating the comparison between the hysteresis loops in the as-annealed OFF (black), treated ON (red) and recovered re-OFF (blue) states. (b,c) Dependence of M on actuation time, during the respective negative and positive voltage steps. (d-f) display the same OFF-ON-OFF information for the Ni 50 Co 50 oxide microdisks.

Article Snippet: A LOT-QuantumDesign MicroSense Vibrating Sample Magnetometer (VSM) was used to characterize the magnetic properties of the samples after annealing.

Techniques: Comparison

Schematic of the cell built for applying an electric field in situ while measuring the magnetic properties in a Vibrating Sample Magnetometer. The electrochemical cell contained the CFO sample as the working electrode and a Pt wire counter electrode. The working electrode contact was made to the Pt underneath the CFO sample. The electrolyte was propylene carbonate with a small amount of dissolved NaOH. The whole cell was attached to a VSM holder and vibrated vertically between the magnetic field coils. The inset shows the layers of the sample from a side view with the Pt counter electrode.

Journal: Scientific Reports

Article Title: Reversible, Electric-Field Induced Magneto-Ionic Control of Magnetism in Mesoporous Cobalt Ferrite Thin Films

doi: 10.1038/s41598-019-46618-6

Figure Lengend Snippet: Schematic of the cell built for applying an electric field in situ while measuring the magnetic properties in a Vibrating Sample Magnetometer. The electrochemical cell contained the CFO sample as the working electrode and a Pt wire counter electrode. The working electrode contact was made to the Pt underneath the CFO sample. The electrolyte was propylene carbonate with a small amount of dissolved NaOH. The whole cell was attached to a VSM holder and vibrated vertically between the magnetic field coils. The inset shows the layers of the sample from a side view with the Pt counter electrode.

Article Snippet: The magnetic properties were measured using a MicroSense (LOT-QuantumDesign) Vibrating Sample Magnetometer (VSM).

Techniques: In Situ